New arrival relay protection testing instrument microcomputer relay tester
Microcomputer Six Phase Secondary Current Injection Test Set Protective Relay Tester for Power Grids
This six phase relay tester is portable and light weight and multifunctional. We have EMC and LVD certification.
Specification about the 6 Phase Electrical Protection Relay Test Kit
AC current Output
Single phase current output (RMS) | 0 -- 30A / phase, accuracy: 0.2% ± 5mA |
Six current in parallel output (RMS) | 0 -- 180A / three phase in phase parallel output |
Duty Cycle | 10A |
Maximum output power per phase | 320VA |
Maximum output power of six phase parallel current | 1000VA |
Maximum output allowable working time of six parallel current | 5s |
frequency Range | 0 -- 1000Hz, accuracy 0.01Hz |
Harmonic number | 2—20 times |
phase | 0—360 o Accuracy: 0.1 o |
DC current Output
DC current output | 0--± 10A / phase, accuracy: 0.2% ± 5mA |
AC voltage output
Single phase voltage output (RMS) | 0 -- 125V / phase, accuracy: 0.2% ± 5mv |
Line voltage output (RMS) | 0--250V |
Phase voltage / line voltage output power | 75VA/100VA |
Frequency range | 0 -- 1000Hz, accuracy: 0.001Hz |
Harmonic wave | 2—20 times |
Phase | 0—360 o Accuracy: 0.1 o |
DC voltage output
Single phase voltage output amplitude | 0--± 150V, accuracy: 0.2% ± 5mv |
Output amplitude of line voltage | 0--±300V |
Phase voltage / line voltage output power | 90VA/180VA |
Numbers of Switch& Measuring time range
Switch input terminal | 8 channels |
Air contact | 1 -- 20 mA, 24 V, internal active output of the device |
Potential reversal | Passive contact: low resistance short circuit signal Active contact: 0-250V DC |
Switch output terminal | 4 pairs, no contact, breaking capacity: 110V / 2A, 220V / 1A |
Time frame | 1ms -- 9999s, measuring accuracy: 1ms |
Dimension and Weight | 390 x 395 x 180 mm, about18kg |
Power Supply | AC125V±10%,50Hz,10A |
Structure of the 6 Phase Electrical Protection Relay Test Kit
1)LED working indication: LED flashing means waiting for work, LED always on means working.
2)Communication interface: The communication is an external notebook computer interface, and the instrument can be controlled through an external notebook computer.
3)USB interface: general interface, can be connected to USB2.0 devices such as mouse, keyboard, U disk, etc.
4)Switch input: used to collect the output switch signal of the protection device and measure time.
5)Switch output: used to control other devices, passive nodes, with a maximum capacity of AC220V/1A.
6)Device auxiliary power supply: It can output DC ±110V power supply, and the maximum current output is 2A, which can supply power to the protection device.
7)The first group and the second group of current output terminals: IA, IB, IC, Ia, Ib, Ic, IN is the common terminal. The LED is on to indicate that the current source is open.
8)The first group and the second group of voltage output terminals: UA, UB, UC, Ua, Ub, Uc, UN are common terminals. The LED is on to indicate that the voltage source is short-circuited.
9)Touchpad: Similar to the laptop touchpad, it can be touch-controlled in all directions. Left and right keys: the left key is the confirmation key, and the right key can view the file properties.
10)Keyboard: Used to input fixed value data.
11)Display screen: The display is a 10.4-inch LED LCD screen.