20A 3 phase transformer winding resistance tester

Short Description:

ITEM: RUN-DCR320AS

The Transformer DC Resistance Tester is a mandatory test item for semi-finished products and finished products factory test, installation and handover test, and preventive test of the power department in the transformer manufacture industry.

It can be used to effectively detect the defects in poor material selection, loose welding and connection parts, missing strands and broken wires of the transformer coil, as well as the operation hidden dangers.

SERVICE:  The instrument will be repaired and replaced free of charge for product quality problems within one year from the date of purchase, and will provide lifetime warranty and

technical services. If you find any abnormalities or malfunctions in the instrument, please contact the company in time to arrange the most convenient solution for you.


Product Detail

Product Tags

Ⅰ: Brief introduction about the 3 PHASE TRANSFORMER WINDING RESISTANCE TESTER

The Transformer DC Resistance Tester is a mandatory test item for semi-finished products and finished products factory test, installation and handover test, and preventive test of the power department in the transformer manufacture industry.

It can be used to effectively detect the defects in poor material selection, loose welding and connection parts, missing strands and broken wires of the transformer coil, as well as the operation hidden dangers. In order to meet the requirements of rapid measurement of transformer DC resistance, a RUN-DCR320AS Winding Resistance Tester with Three-Phase simultaneous test function, Magnetic Augment Function, and Degauss Function into one body has been developed in our company. The tester has the functions of three-phase simultaneous power-on, independent current and voltage sampling, simultaneous measurement and display of three-phase resistance and three-phase unbalance rate, so as to greatly shorten the test period of transformer DC resistance and solve the problems about long time consumption for DC resistance measurement of each tap winding in power transformers.

Ⅱ: Parameters of the DC RESISTANCE TESTER

 

    10A  20A  40A
Current Three-Phase 5A+5A
1A+1A
200mA+200mA
10A+10A
5A+5A
1A+1A
20A+20A
10A+10A
5A+5A
1A+1A
200mA+200mA
25A+25A
10A+10A
5A+5A
1A+1A
200mA+200mA
Single- Phase 10A/5A/1A/200mA/20mA 20A/10A/5A/1A/200mA 40A/20A/10A/5A/1A/200mA/20mA 50A/20A/10A/5A/1A/200mA/20mA
Range Three-Phase 5A+5A:2mΩ~1.2Ω
1A+1A:10mΩ~6Ω 200mA+200mA:
50mΩ~30Ω
10A+10A:1mΩ~0.6Ω
5A+5A:2mΩ~1.2Ω
1A+1A:10mΩ~6Ω
20A+20A:0.5mΩ~0.3Ω
10A+10A:1mΩ~0.6Ω
5A+5A:2mΩ~1.2Ω
1A+1A:10mΩ~6Ω
200mA+200mA:50mΩ~30Ω
25A+25A:0.4mΩ~0.1Ω10A+10A:1mΩ~0.6Ω
5A+5A:2mΩ~1.2Ω
1A+1A:10mΩ~6Ω200mA+200mA:50mΩ~30Ω
Single-Phase 10A:1mΩ~2Ω
5A:2mΩ~4Ω
1A:10mΩ~20Ω
200mA:100mΩ~100Ω
20mA:10Ω~20KΩ
20A:0.5mΩ~1Ω10A:1mΩ~2Ω
5A:2mΩ~4Ω
1A:10mΩ~20Ω200mA:100mΩ~100Ω
40A:0.25mΩ~0.5Ω
20A:0.5mΩ~1Ω
10A:1mΩ~2Ω
5A:2mΩ~4Ω
1A:10mΩ~20Ω
200mA:100mΩ~100Ω
20mA:10Ω~20KΩ
50A:0.20mΩ~0.3Ω
20A:0.5mΩ~1Ω
10A:1mΩ~2Ω
5A:2mΩ~4Ω
1A:10mΩ~20Ω
200mA:100mΩ~100Ω
20mA:10Ω~20KΩ
Accuracy ±0.2%+2 digits
Best Resolution 0.1μΩ
Working Temperature -10~40℃
Power Supply AC220V±10%, 50Hz±1Hz

 

Ⅲ: Show some detailed pictures

transformer dc resistance tester
DCR tester
transformer test
3 channels winding resistance tester

Ⅳ: Features of the winding resistance tester

* The tester can select corresponding output current value according to test products, and is mainly suitable for measuring the inductive DC resistance on transformers;
* On large transformers with a five-leg core and low-voltage windings connected in delta, the tester can be used for the test in HV & LV series excitation mode. The magnetic augment circuit of the windings can be automatically connected in the tester, to quickly and accurately test the DC resistance of the low-voltage windings;
* The tester has a Three Phases Test function to measure the three-phase DC resistance of the star-connected windings synchronously and calculate the three-phase unbalance rate automatically, so as to greatly reduce the measurement period and improve the test efficiency. Its phase by phase test function can also be used for phase by phase test on transformers with YN and D (Y) connections;
* The winding material can be set according to the winding material of the transformer, such as copper or aluminum, to distinguish the conversion temperature coefficient of different materials.
* The tester is equipped with transformer YN winding neutral point lead line resistance detection function, can make three-phase test data closer to the single-phase test value.
* The tester has a complete protection circuit and sound discharge alarm, to inform the clear discharge indication and reduce the mis operation;
* The tester is equipped with a 7-inch color touch screen. to display the test data clearly in real-time;
* The tester has Chinese and English operation interfaces, which can be configured according to the user requirements;
* The tester is equipped with a RS232 communication port, to transmit the test data to the background, with the control software in the host computer; equipped with a USB port, built-in calendar and clock, as well as saving(save 100 groups of data), review, and printing functions of test data;
* The tester has more complete parameter settings, including test windings, Tapping Positions, test phases, Tested Sample Temperature, Conversion Temperature and others of the transformers;
* The tester is equipped with an industrial plastic case which ensures its good portability and improves its service life.


  • Previous:
  • Next:

  • Leave Your Message:

    Leave Your Message:

    Write your message here and send it to us.